Service hotline:+86 40009 63336

©2019 All rights reserved.

Sitemap  |  鲁ICP备17045620号   网站建设:中企动力青岛

Links:

Online consultation

Working hours: Daily 08:00-23:00
Welcome to add QQ customer service consultation
QQ: 1968322180

+86 40009 63336

Welcome to call the national hotline
Working hours: Daily 08:00-20:00
Complaint call: +86-532-80969903

Micro-channel public platform

Alibaba online shopping mall

Products

Medical cylinder

Product description
First, the product name
Chinese name: medical cylinder
English name: seamless aluminium alley gas cylinder
Second, product introduction
1. Medical oxygen refers to the use of cryogenic separation to separate oxygen from the atmosphere to supply oxygen for medical treatment of patients.
2. Applicable to the adjuvant treatment of respiratory diseases caused by hypoxia (such as asthma, bronchitis, pulmonary heart disease, etc.), heart and cerebrovascular diseases (such as coronary heart disease, myocardial infarction, cerebral hemorrhage, cerebral infarction) Its hypoxia symptoms; can also be used for health care oxygen or nervous mental work and rapid relief of fatigue after physical labor.
Third, common uses
1. Ingestion disorders: Respiratory diseases such as asthma are the most common cases of hypoxia caused by ingestion disorders, which can seriously affect life learning and work. In addition, an anoxic environment such as a basement where air does not circulate and an indoor space that does not ventilate during winter are obstacles to intake caused by external factors. The hunchback, chest-bearing and other bad postures make the lungs unable to fully stretch during breathing and cause hypoxia, which is caused by insufficient oxygen ventilation.
2. Disorders of transport: Oxygen is transported throughout the body primarily through our blood. Therefore, if there is an obstacle in our blood transport, it will cause hypoxia in human tissues, and the result of hypoxia in human tissues is the occurrence of lesions. Such as coronary heart disease: refers to ischemic heart disease caused by myocardial hypoxia (insufficient blood supply) caused by stenotic coronary artery disease. Atherosclerosis: the thickening and hardening of the arterial wall, the general term for the degenerative and proliferative lesions of the lumen, the narrowing and narrowing of the lumen of the blood vessels naturally leads to poor blood circulation, which causes tissue hypoxia, leading to lesions. And necrosis. Cerebrovascular disease: cerebral vascular embolism and other causes of brain tissue hypoxia and other essential nutrients lead to tissue lesion necrosis. Anemia: The amount of red blood cells in the blood responsible for transporting medical oxygen or the amount of hemoglobin in red blood cells is insufficient, resulting in an obstacle to oxygen transport.
3. Excessive consumption: The longest thing is to use people with excessive brain. Excessive use of the brain for a long time can cause hypoxia in the brain, which leads to learning, work efficiency, slow response, and nighttime sleep disorders. In addition, lactic acid is the cause of the body's feeling of soreness and fatigue. Lactic acid is a product of tissue anaerobic glycolysis under conditions of insufficient oxygen supply. Therefore, from the perspective of supplementing physical fitness and improving brain vitality, if you can't improve your body's hypoxia through exercise, you can take some medical oxygen.
Fourth, the packaging specifications
 

Product name

Cylinder model

Diameter (mm)

Volume (L)

Height (mm)

Weight (kg)

Working pressure (MPa)

Wall thickness (mm)

Bottle material

Medical cylinder

2L

140

2.5

300

5.5

15

3.6

37Mn

Medical cylinder

3L

140

3.0

345

6.1

15

3.6

37Mn

Medical cylinder

4L

140

4.0

395

7.1

15

3.6

37Mn

Medical cylinder

8L

140

8.0

680

11.5

15

3.6

37Mn

Medical cylinder

10L

152

10

710

13.5

15

4.0

37Mn

Medical cylinder

15L

152

15

1020

18.5

15

4.0

37Mn

Medical cylinder

20L

219

20

715

28

15

5.7

37Mn

Medical cylinder

25L

219

25

865

33

15

5.7

37Mn

Medical cylinder

30L

219

30

1015

38

15

5.7

37Mn

Medical cylinder

35L

219

35

1165

43

15

5.7

37Mn

Medical cylinder

40L

219

40

1315

48

15

5.7

37Mn

Medical cylinder

50L

219

50

1615

58

15

5.7

37Mn

 
Fifth, the production process
1. Overall punching type:
Billet sawing and cutting - induction heating - anti-extrusion punching - drawing - picking - closing - heat treatment - external sandblasting - mouth thread processing - internal sandblasting (or phosphating) treatment - hydraulic test - upper valve -Airtight test-spray-drying-inspection-inbound
2. Steel pipe spinning method:
Steel pipe sawing and cutting - induction heating - spinning seal bottom - milling insole - induction heating - spinning pressure closing - heat treatment - sand blasting - mouth thread processing - internal sandblasting (or phosphating) treatment - hydraulic test - upper valve -Airtight test-spray-drying-inspection-inbound
Sixth, matters needing attention
1. The warehouse should be cool and ventilated, away from heat sources, fire, and prevent sun exposure. It is strictly forbidden to be heated. Explosion-proof lighting should be used for lighting in the library. No flammable materials should be stacked around the warehouse.
2. Attention should be paid to the acceptance of gas cylinders: the shape of the package is not obvious, the accessories are complete, the closure is tight, and there is no air leakage. The use period of the packaging should be within the period of pressure test. If it is overdue, it cannot be postponed and must be re-tested.
3. Gas cylinders whose contents are mutually contraindicated shall be stored in separate warehouses. For example, hydrogen bottles and liquid chlorine bottles, hydrogen bottles and oxygen bottles, liquid chlorine bottles and liquid ammonia bottles, etc., are not allowed to be mixed with the library. Flammable gases should not be stored together with other types of chemical dangerous goods. The cylinders should be placed upright when stored, preferably secured by a frame or fence and with access.
4. It must be lightly loaded and unloaded during loading and unloading. It is strictly forbidden to collide, throw, slide or roll on the ground. Do not point the valve to the person, and take care to prevent the cylinder helmet from falling off. Work clothes and handling tools must not be contaminated with oil when handling oxygen cylinders. Flammable gases are strictly prohibited from contact with fire.
5. The valve in the storage should be tightened and must not be leaked. If the cylinder is leaking, the door should be quickly opened, the cylinder valve should be tightened, and the cylinder should be immediately moved to a safe place. If it is a toxic gas, wear a gas mask. When the fire occurs, the gas cylinder should be removed from the fire as soon as possible. If it is not transported, a large amount of water can be used to cool the gas cylinder to prevent the high temperature from causing the gas cylinder to explode. Firefighters should stand on the upwind and on the side of the cylinder.
6. The helmet on the cylinder must be worn when transporting. Gas cylinders should generally be laid flat, and the mouth of the bottle should be oriented in the same direction, and should not be crossed; the height should not exceed the fence of the vehicle, and the triangular wooden mat should be used to prevent rolling.
7. All gas cylinders must undergo regular technical inspections in strict accordance with national regulations. If the gas cylinder is found to have severe corrosion or other serious damage during use, it should be inspected in advance.
8. When storing and transporting cylinders, check:
(1) Whether the paint color and logo on the bottle match the product name on various documents, whether the packaging, logo, and anti-vibration apron are complete, and whether the bottle seal on the bottle is within the validity period.
(2) Whether the helmet is intact, tightened, and the bottle wall is corroded, damaged, crusted, sunken, bubbling and scars.
(3) Whether the earphones have a “filament” leaking sound.
(4) Detect the presence of strong irritating odor or odor on the spot by smell.
Note: The above gas cylinder specifications are general reference materials. If you have special requirements, please call 40009 63336, 18563963366

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待
Previous article
Next article